    The ADI-M is a universal input and output module for connection to the central bus with 4 resistance-monitored inputs (measuring range 2 kOhm to 300 kOhm) and 4 open-collector outputs. A unique feature is the resistance range for monitoring that can be configured individually for each input. This means that a wide variety of detector types can be connected or taken over from existing installations. In addition, the inputs support "Triple End of Line" resistors for the detection of alarm, sabotage and cover protection with one input, individual delay times per input as well as the possibility to configure each input as a digital input. The open-collector outputs are active by default, then a GND is available on these terminals. The maximum continuous output current per output is 350 mA each. A briefly higher inrush current (for example for switching inductive loads) is also supported.
  • Technical data

    Technical data

    Current consumption

    7mA

    Inputs

    4

    Measuring range

    1,5 - 300k Ohm

    Outputs open collectors

    4

    Tamper protection

    2

    Operating temperature

    0 - 40 °C

    Fuse

    2 x 200mA

    Supply voltage

    9 -16VDC

    Approval EN

    50131 Grade 3

  • Accessory

  • Documentation
  • Description

    Description

    System housing for Siveillance Intrusion BUS elements. The GE2 housing is suitable for the ADI-M plug-in units and the SMB M gateway. High quality double spring terminals for efficient connection up to 1.5mm2 wire.
  • Technical data

    Technical data

    Dimensions (W x H x D)

    83 x 139 x 46mm

    Housing protection (EN 60529 / IEC 529)

    IP51

    Approval EN

    50131 Grade 3

    Material

    ABS

  • Accessory

  • Documentation
  • Description

    Description

    The BUS module IR3 allows the detector to be connected directly to the N-BUS bus. The detector is thus individually addressed and monitored. A simple bus topology with 4 wires can thus be set up. Existing ring bus configurations can also be adopted. Walk test and arm / disarm signal from the control center are supported. Sensitivity is set in the detector.
  • Technical data

    Technical data

    Supply voltage

    N-BUS 9..15VDC

    Power consumption

    5mA

    Operating conditions Temperature

    0 - 40°C

    Operating conditions Humidity

    93%

    Inputs

    3

    Outputs open collectors

    2

  • Documentation
  • Description

    Description

    The RPT N-BUS repeater can be used either as a bus repeater (electrical segmentation to extend the RS 485 bus) or as a serial gateway (RS 232) to connect a PC or other components with RS232 interface (e.g. fibre optic converters).
  • Technical data

    Technical data

    Dimensions (W x H x D)

    85 x 66 x 27mm

    Current consumption

    20mA

    Current consumption: maximum

    40mA

    Cable length

    N-BUS 120m max.
    RS232 / 3m max.

    Tamper protection

    Yes

    Operating temperature

    0 - 40°C

    Fuse

    F1 1A (3A max)

    Supply voltage

    8 - 16V

    Housing protection (EN 60529 / IEC 529)

    IP 20

    Approval EN

    EN 50131 Grade 3

    Approval VdS

    Class-C

  • Documentation
  • Description

    Description

    The LSN-GW module is used to connect an LSN ring bus to the N-bus of Intrusion PRO / ADV systems.
    Up to 4 LSNi-GWs can be connected to a PRO-300/400-C Intrusion control panel. One ring or two stubs are available for each LSN-GW. With the LSN-GW, higher bus current limits can be achieved, depending on the cable length (max. 300mA). The bus current is automatically regulated and the limit values are managed dynamically. Basically, the bus elements are operated in LSN Classic mode with a maximum number of 127 elements and a cable length of max. 1000 m.
  • Technical data

    Technical data

    Dimensions (L x W x H)

    160 x 100 x 25mm

    Supply voltage

    9...30VDC

    Input contacts

    1

    Current consumption

    420mA

    Number of adresses

    LSN 127 Modules

    Serial interfaces

    1 / N-BUS

    Cable length

    LSN 1000max.

  • Documentation
  • Description

    Description

    The M-Bus Gateway takes over 1:1 up to 40 existing M-BUS Module from older Siemens Intrusion Detection Systems: CS440, CS6, CS4 Series including the connected detectors.
  • Technical data

    Technical data

    Field bus

    Siemens M-Bus

    Tamper contact

    Yes

    Max. number of hardwired zones

    160

    Operating voltage

    15 VDC

    System compatibility

    Guarto CS9 MP6 or higher

  • Accessory

  • Documentation
  • Description

    Description

    The LAN-Modul-TR is used for the transparent implementation of a serial interface on a LAN (TCP or UDP). Optionally, a direct point-to-point connection (serial LAN / LAN-serial) can be implemented when using two modules. The module can be used as an N-BUS extension via IP-Ethernet and generation of further N-BUS interfaces on the Intrusion PRO / ADV system or as a conversion of an RS232, RS485 interface to LAN / IP-Ethernet (and back)
  • Technical data

    Technical data

    Dimensions (L x W x H)

    48 x 53 x 126mm

    Supply voltage

    5-30V

    Power consumption

    100mA

    Weight net

    0.095Kg

    Operating conditions Temperature

    0-50°C

    Interfaces

    RS232, RS485, USB

    Weight

    95g

    LAN/Ethernet

    RJ45 Ethernet 10BASE-T / 100BASE-TX
    (auto-sensing)

  • Documentation
  • Description

    Description

    The LWL / LON / RS485 module is used for coupling between a LON or RS485 field bus and a cabling based on optical fibres (LWL) or 4-wire telecommunication cable.
    In conjunction with an appropriate fibre-optic or 4-wire module, connection distances of several kilometres can be realised. The permissible attenuation values of the fibre optic modules or the line data and the environmental conditions of the telecommunications cables must be observed.
    environmental conditions of the telecommunication cables. Fibre optic cables are preferred in projects with special EMC (electromagnetic compatibility) requirements and also offer a higher level of protection against manipulation.
    Depending on the requirements of the customer or an already existing infrastructure
    two different fibre optic modules and a 4-wire module are available:
  • Technical data

    Technical data

    Dimensions (L x W x H)

    50 x 55 x 126mm

    Power consumption

    55mA

    Weight net

    96 gr

    Serial interfaces

    RS485 / 9,6 - 500kBit

    Power supply

    8,5 - 30VDC

    Environmental class

    II (-10 bis +55 °C)

    Ambient temperature, operating

    -10 ... +55°C