Control panels & power supply
-
Description
Description
The control ADV panel is the entry to the Siveillance Intrusion - Advanced Burglar alarm system. It includes all essential system components such as CPU module, power supply, interface modules, input and output modules. Depending on requirements, additional modules can be installed. -
Technical data
Technical data
Dimensions (L x W x H)
240 x 380 x 101 mm
Operating temperature range
0 - 40C
Humidity (no condensation permitted)
93% rF
Weight
3,4 Kg
Supply voltage (typical)
230VAC
Output current
1,3 A
Input (power consumption)
100VA
Current consumption
80mA
Room for battery
1 x 17AH /12V VRLA
Tamper contact
Yes
Inputs
8
Outputs open collectors
8
Output relay (on board)
2 x 30VDC / 0.6Amax.
Bus connections
1
Devices per bus / bus segment
127
Number of partitions
100
Users
1000
Ethernet-Interfaces
1 (100Mbit/s)
Outputs
12 Open Collector
Approval
EN 50131 Grade 3
- Documentation
-
Description
Description
The control unit ADV - 200 is the core element of the Siveillance intrusion
Advanced Intrusion alarm system. It includes all essential system components such as CPU module, power supply, interface modules, input and output modules. Depending on requirements, additional modules can be installed. -
Technical data
Technical data
Dimensions (L x W x H)
502,5 x 350 x 155 mm
Operating temperature range
20-40°C
Humidity (no condensation permitted)
93%rF max.
Weight
10kg
Supply voltage (typical)
230V
Output current
1,3A
Input (power consumption)
220VA
Current consumption
80mA
Room for battery
1 x 26Ah VRLA or 1 x 45Ah VRLA
Tamper contact
1
Inputs
8
Outputs open collectors
8
Output relay (on board)
2 x 30VDC / 0.6A max.
Bus connections
1
Devices per bus / bus segment
127
Number of partitions
100
Users
1000
Ethernet-Interfaces
1 (100Mbit/s) RJ45
Approval
EN 50131 Grade 3
- Documentation
-
Description
Description
The control panel is the core component of the Siveillance Intrusion - PRO Burglar alarm system. It includes all essential system components such as CPU module, power supply, interface modules, input and output modules. Depending on requirements, additional modules can be installed. -
Technical data
Technical data
Dimensions (L x W x H)
604 x 404 x 105
Operating temperature range
0 - 40C
Humidity (no condensation permitted)
20% - 90% rF
Weight
14 Kg
Supply voltage (typical)
230VAC
Current consumption
200mA
Room for battery
2 x 17Ah/12V VRLA
Tamper contact
2
Inputs
4
Output relay (on board)
8 x max. 30VDC / 0.6A
Open collector output
4 x 350mA
Bus connections
3
Devices per bus / bus segment
200 / 128
Number of partitions
4000
Users
10000
Ethernet-Interfaces
1 x RJ45, (100Mbit/s)
- Documentation
-
Description
Description
The control panel is the core component of the Siveillance Intrusion - Pro Burglar alarm system. It includes all essential system components such as CPU module, power supply, interface modules, input and output modules. Depending on requirements, additional modules can be installed. -
Technical data
Technical data
Dimensions (L x W x H)
700 x 500 x 250mm
Operating temperature range
0-40°C
Humidity (no condensation permitted)
93% rF
Weight
16Kg
Supply voltage (typical)
230VAC
Input (power consumption)
220VA
Current consumption
200mA
Room for battery
2 x 40Ah/12V VRLA
Tamper contact
1
Inputs
4
Output relay (on board)
8 x max. 30VDC / 0.6A
Open collector output
4 x 350A max.
Bus connections
3
Devices per bus / bus segment
200 / 128
Number of partitions
4000
Users
10000
Ethernet-Interfaces
1 x RJ45, (100Mbit/s)Approval
EN 50131 Grade 3
VdS C - Documentation
-
Description
Description
The auxiliary power supply ADV-100-PS is as an independent additional power supply with a battery capacity of 17SAh for the separate supply of detectors, modules and other consumers. The ADV-100-PS can be installed at the location of the controller PRO or ADV-xxxC or as an independent component in the field . The status information is transmitted via the 4-wire communication N-BUS. -
Technical data
Technical data
Dimensions (L x W x H)
240 x 101 x 380mm
Output current
1,3 A
Tamper contact
Yes
Approval
EN 50131
Operating temperature
25..40°C
Weight (without battery)
3,3 kg
Output voltage
15,5 VAC
Battery type
1 x 17Ah VRLA
Power supply
230 VAC
- Documentation
-
Description
Description
The auxiliary power supply ADV-200-PS is as an independent additional power supply with a battery capacity of 45 Ah for the separate supply of detectors, modules and other consumers. The ADV-200-PS can be installed at the location of the controller ADV-200-C or as an independent component in the field.
The status information is transmitted via the 4-wire communication bus. -
Technical data
Technical data
Dimension (L x B x H)
lkjlk
-
Description
Description
The auxiliary power supply PRO-300-PS can be used as an independent additional power supply with a battery capacity of 2x17Ah Ah for the separate supply of detectors, couplers and other power consumers. The ADV-300-PS can be installed at the location of the controller ADV-300-C or as an independent component in the field.
-
Description
Description
The auxiliary power supply PRO-400-PS is as an independent additional power supply with a battery capacity of 80AH for the separate supply of detectors,
modules and other consumers. The PRO-400-PS can be installed at the location of the controller PRO-400-C or as an independent component in the field . The status
information is transmitted via the 4-wire communication bus.